# Displacement response = Nanometrics Trillium Compact + ED # Seismometer sensitivity from manual 749.1 Vs/m # ED sensitivity 1000000 counts/V # System sensitivity 749.1x1000000 = 0.74910 counts/nm/s # Normalization factor 8.184e+11 (from Trillium manual) # std conts. => 0.74910 x 8.184e+11 = 6.1306344e+11 theoretical 1 instrument paz Kortstrom 6.1306344e+11 7 -0.03691 0.03712 0.0000000000e+00 0.0000000000e+00 -0.03691 -0.03712 0.0000000000e+00 0.0000000000e+00 -371.2 0.00000 0.0000000000e+00 0.0000000000e+00 -373.9 475.5 0.0000000000e+00 0.0000000000e+00 -373.9 -475.5 0.0000000000e+00 0.0000000000e+00 -588.4 1508 0.0000000000e+00 0.0000000000e+00 -588.4 -1508 0.0000000000e+00 0.0000000000e+00 4 -434.1 0.00000 0.0000000000e+00 0.0000000000e+00 0.000 0.00000 0.0000000000e+00 0.0000000000e+00 0.000 0.00000 0.0000000000e+00 0.0000000000e+00 0.000 0.00000 0.0000000000e+00 0.0000000000e+00